10 Tips for Making a Good SERVICE ΚΛΙΜΑΤΙΣΤΙΚΩΝ Even Better

An air conditioning system's filters, coils, and fins need routine maintenance for the unit to work efficiently and efficiently throughout its years of service. Disregarding required maintenance makes sure a constant decline in a/c efficiency while energy use steadily increases. Take a look at our Energy Saver 101 Infographic: House Cooling for more ways to help improve your comfort and the efficiency of your a/c.

Air Conditioner Filters

The most important maintenance job that will ensure the efficiency of your air conditioning unit is to consistently replace or clean its filters. Obstructed, unclean filters obstruct typical air flow and decrease a system's performance significantly. With typical air flow blocked, air that bypasses the filter may carry dirt straight into the evaporator coil and hinder the coil's heat-absorbing capability. Replacing an unclean, blocked filter episkevi klimatistikon athina with a tidy one can reduce your ac system's energy usage by 5% to 15%.

For central air conditioners, filters are typically located somewhere along the return duct's length. Typical filter locations are in walls, ceilings, furnaces, or in the air conditioner itself. Space air conditioning unit have a filter mounted in the grill that deals with into the space.

Some types of filters are multiple-use; others should be replaced. They are offered in a variety of types and performances. Clean or replace your cooling system's filter or filters every month or more during the cooling season. Filters may require more frequent attention if the air conditioning system is in continuous usage, is subjected to dirty conditions, or you have fur-bearing pets in the house.

Air Conditioner Coils

The air conditioning system's evaporator coil and condenser coil gather dirt over their months and years of service. A clean filter avoids the evaporator coil from soiling rapidly. In time, nevertheless, the evaporator coil will still collect dirt. This dirt reduces airflow and insulates the coil, minimizing its ability to soak up heat. To avoid this problem, inspect your evaporator coil every year and clean it as essential.

Outside condenser coils can also become extremely dirty if the outside environment is dirty or if there is foliage close by. You can easily see the condenser coil and notification if dirt is collecting on its fins.

You need to decrease dirt and particles near the condenser unit. Your dryer vents, falling leaves, and lawn mower are all potential sources of dirt and debris. Cleaning up the area service air condition athina around the coil, getting rid of any debris, and trimming foliage back at least 2 feet (0.6 meters) permit appropriate air flow around the condenser.

Coil Fins

The aluminum fins on evaporator and condenser coils are quickly bent and can obstruct airflow through the coil. Cooling wholesalers sell a tool called a "fin comb" that will comb these fins back into almost initial condition.

Condensate Drains pipes

Periodically pass a stiff wire through the system's drain channels. Blocked drain channels avoid a system from decreasing humidity, and the resulting excess wetness might discolor walls or carpet.

Window Seals for Room Air Conditioners

image

At the start of each cooling season, inspect the seal between the air conditioning unit and the window frame to ensure it reaches the system's metal case. Moisture can damage this seal, enabling cool air to leave from your house.

Preparing for Winter season

In the winter, either cover your space air conditioning system or get rid of and store it. Covering the outdoor unit of a central air conditioning SERVICE ΚΛΙΜΑΤΙΣΤΙΚΩΝ conditioner will protect the system from winter weather condition and particles.

Working with an Expert

When your air conditioning system needs more than regular maintenance, work with a professional service professional. A trained professional will discover and fix problems in your a/c system.

The service technician ought to:

Look for proper quantity of refrigerant

Test for refrigerant leakages using a leak detector

Record any refrigerant that should be left from the system, instead of illegally launching it to the atmosphere

Check for and seal duct leak in main systems

Procedure airflow through the evaporator coil

Validate the appropriate electric control series and make certain that the heating system and cooling system can not run concurrently

Check electric terminals, clean and tighten up connections, and apply a non-conductive finishing if essential

Oil motors and examine belts for tightness and wear

Examine the accuracy of the thermostat.